The measurement system for attribute data (type of defect, categories, survey rankings, etc.) requires a different analysis than continuous data (time, length, weight, etc.). For continuous data, you ...
Attribute Gage R&R reveals two important findings – the percentage of repeatability and the percentage of reproducibility. Ideally, both percentages should be 100 percent, but generally ...
Figure A.3 shows a sample gage report created with the GAGE application using the average and range method. The measures of repeatability, reproducibility, gage R&R, part variation, and total ...